{"id":4410,"date":"2026-03-10T03:48:22","date_gmt":"2026-03-10T03:48:22","guid":{"rendered":"https:\/\/hysfsubsea.com\/knowledge-base\/mcil-10-pin-underwater-connectors-complete-specifications-and-applications-guide\/"},"modified":"2026-03-10T03:48:22","modified_gmt":"2026-03-10T03:48:22","slug":"mcil-10-pin-underwater-connectors-complete-specifications-and-applications-guide","status":"publish","type":"knowledge-base","link":"https:\/\/hysfsubsea.com\/ar\/knowledge-base\/mcil-10-pin-underwater-connectors-complete-specifications-and-applications-guide\/","title":{"rendered":"\u0645\u0648\u0635\u0644\u0627\u062a MCIL \u0630\u0627\u062a 10 \u0633\u0646\u0648\u0646 \u062a\u062d\u062a \u0627\u0644\u0645\u0627\u0621: \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0648\u062f\u0644\u064a\u0644 \u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a"},"content":{"rendered":"<p><strong>\u0625\u062c\u0627\u0628\u0629 \u0633\u0631\u064a\u0639\u0629:<\/strong> HYSF MCIL 10-pin underwater connectors (MCIL10M male and MCIL10F female) are inline cable-to-cable connectors designed for multi-channel subsea applications. Featuring 5\/8&#8243;-18 UNF thread, 10 gold-plated contacts, stainless steel housing, and depth ratings up to 3000m. Ideal for ROV systems, underwater sensors, and marine instrumentation. Standard delivery is 5-7 days for 100-piece orders.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0627\u0644\u0634\u0631\u062d \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a<\/h2>\n\n\n\n<p>The MCIL series is HYSF&#8217;s premium inline underwater connector family, designed for reliable cable-to-cable connections in demanding marine environments. The 10-pin configuration (MCIL10M\/MCIL10F) offers an optimal balance of pin count, size, and current capacity for complex subsea systems.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">MCIL10 Series Specifications<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">MCIL10M (Male)<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">MCIL10F (Female)<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Pin Count<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">10 pins (gold-plated brass contacts)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Thread Size<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">5\/8&#8243;-18 UNF-2A<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Current Rating<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">5A per contact (continuous)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Voltage Rating<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">Up to 400V<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Insulation Resistance<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">\u22651000 M\u03a9 @ 500V DC<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Contact Resistance<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">\u226410 m\u03a9<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>\u062a\u0635\u0646\u064a\u0641 \u0627\u0644\u0639\u0645\u0642<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">100m, 300m, 1000m, 3000m (standard)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Housing Material<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">316L Stainless Steel (standard), Titanium (optional)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Sealing<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">Double O-ring (Viton standard)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Temperature Range<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\" colspan=\"2\">-40\u00b0C to +85\u00b0C<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Cable Entry<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">6-12mm OD<\/td><td style=\"border:1px solid #ddd;padding:8px;\">6-12mm OD<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Termination<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">Solder cup or crimp<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Solder cup or crimp<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">MCIL Series vs MCBH Series<\/h3>\n\n\n\n<p>Understanding the difference between MCIL (inline) and MCBH (bulkhead) connectors:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Feature<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">MCIL (Inline)<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">MCBH (Bulkhead)<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Mounting Style<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">Cable-to-cable connection<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Panel\/housing penetration<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Typical Application<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">Cable extensions, junctions<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Sensor housing, equipment walls<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Installation<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">In-line with cable run<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Mounted through bulkhead\/panel<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Housing Design<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">Cylindrical, cable entry on both ends<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Flanged, cable entry on one side<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Typical Applications for 10-Pin Connectors<\/h3>\n\n\n\n<p>The 10-pin configuration is ideal for applications requiring multiple signal and power channels:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Application<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Typical Pin Assignment<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Industry<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>ROV Control Systems<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">4x motor control + 4x sensor data + 2x power<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Underwater robotics<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Multi-Parameter Sensors<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">6x sensor channels + 4x power\/ground<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Oceanographic research<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Underwater Cameras<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">2x video + 2x control + 4x power + 2x lighting<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Inspection\/Survey<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>Hydrophone Arrays<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">8x audio channels + 2x power<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Acoustic monitoring<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\"><strong>AUV Communication<\/strong><\/td><td style=\"border:1px solid #ddd;padding:8px;\">4x data + 2x control + 4x power<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Autonomous vehicles<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Pin Configuration Options<\/h3>\n\n\n\n<p>MCIL10 connectors support flexible pin assignments for mixed signal and power applications:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Standard Configurations<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>All Signal:<\/strong> 10x signal pins (RS232, RS485, Ethernet, analog)<\/li>\n<li><strong>Mixed (6+4):<\/strong> 6x signal + 4x power (common for powered sensors)<\/li>\n<li><strong>Mixed (8+2):<\/strong> 8x signal + 2x power (data-intensive applications)<\/li>\n<li><strong>Mixed (4+6):<\/strong> 4x signal + 6x power (power-intensive devices)<\/li>\n<li><strong>All Power:<\/strong> 10x power pins (high-current distribution)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Custom Pin Assignments<\/h4>\n\n\n\n<p>For specific applications, HYSF can configure custom pin assignments:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Specify pin-by-pin requirements (e.g., Pin 1-4: RS485, Pin 5-8: 12V power, Pin 9-10: ground)<\/li>\n<li>Provide wiring diagram or pinout table<\/li>\n<li>We&#8217;ll configure connectors and provide test reports<\/li>\n<li>No additional charge for standard custom pinouts (100+ piece orders)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Cable Compatibility<\/h3>\n\n\n\n<p>MCIL10 connectors are designed for multi-conductor underwater cables:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;\">Cable Parameter<\/th><th style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\">Conductor Count<\/td><td style=\"border:1px solid #ddd;padding:8px;\">10+ conductors (recommended)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Conductor Size<\/td><td style=\"border:1px solid #ddd;padding:8px;\">0.14-1.5mm\u00b2 (26-16 AWG)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Cable OD<\/td><td style=\"border:1px solid #ddd;padding:8px;\">6-12mm (fits standard cable glands)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Cable Type<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Multi-conductor shielded underwater cable<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Jacket Material<\/td><td style=\"border:1px solid #ddd;padding:8px;\">PU, TPU, PE (compatible with connector backshell)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Installation and Termination<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Termination Methods<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Solder Cup:<\/strong> Traditional method, reliable connections, requires soldering skill<\/li>\n<li><strong>Crimp Contacts:<\/strong> Faster, more consistent, requires crimping tool (recommended for production)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Installation Steps<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Prepare Cable:<\/strong> Strip outer jacket to expose individual conductors (15-20mm)<\/li>\n<li><strong>Strip Conductors:<\/strong> Strip each conductor insulation (3-5mm for solder cups)<\/li>\n<li><strong>Tin Wires:<\/strong> Apply solder to wire ends for easier insertion<\/li>\n<li><strong>Solder\/Crimp:<\/strong> Attach wires to contact tails (follow pin assignment diagram)<\/li>\n<li><strong>Insert into Housing:<\/strong> Carefully place terminated insert into connector body<\/li>\n<li><strong>Install Backshell:<\/strong> Secure cable with strain relief and backshell nut<\/li>\n<li><strong>\u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631:<\/strong> Perform continuity and insulation resistance tests<\/li>\n<li><strong>Seal:<\/strong> Apply thread sealant (optional) and mate connectors<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\">Required Tools<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Wire Strippers:<\/strong> Precision strippers for small gauge wires (0.14-1.5mm\u00b2)<\/li>\n<li><strong>Soldering Iron:<\/strong> Temperature-controlled, fine tip (for solder cup termination)<\/li>\n<li><strong>Crimping Tool:<\/strong> Ratcheting crimper for consistent crimps (for crimp contacts)<\/li>\n<li><strong>Multimeter:<\/strong> For continuity testing<\/li>\n<li><strong>Megohmmeter:<\/strong> For insulation resistance testing (recommended)<\/li>\n<li><strong>Torque Wrench:<\/strong> For proper backshell tightening (0.8-1.2 N\u00b7m)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Material Selection<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Component<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Standard Material<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">Options<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\">Housing<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0641\u0648\u0644\u0627\u0630 \u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 316L<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Titanium (for 6000m depth)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">\u062c\u0647\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Brass, gold-plated<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Beryllium copper (high cycle)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">O-Rings<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Viton (FKM)<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Silicone, EPDM<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Backshell<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0641\u0648\u0644\u0627\u0630 \u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 316L<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Titanium, Aluminum<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">Insert<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Engineering plastic (POM)<\/td><td style=\"border:1px solid #ddd;padding:8px;\">PEEK (high temperature)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Ordering Information<\/h3>\n\n\n\n<p>When ordering MCIL10 connectors, please specify:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Model:<\/strong> MCIL10M (male) or MCIL10F (female)<\/li>\n<li><strong>Quantity:<\/strong> Number of pieces (pairs recommended)<\/li>\n<li><strong>Depth Rating:<\/strong> 100m, 300m, 1000m, or 3000m (standard)<\/li>\n<li><strong>Housing Material:<\/strong> 316L SS (standard) or Titanium<\/li>\n<li><strong>Termination Type:<\/strong> Solder cup or crimp contacts<\/li>\n<li><strong>Pin Configuration:<\/strong> Standard or custom pinout<\/li>\n<li><strong>Cable Entry:<\/strong> Cable OD range (6-12mm standard)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Pricing and Lead Time<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"width:100%;border-collapse:collapse;\"><thead><tr><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">\u0627\u0644\u0643\u0645\u064a\u0629<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">\u062e\u0635\u0645<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">\u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629<\/th><th style=\"border:1px solid #ddd;padding:10px;background:#2c5282;color:white;\">\u0627\u0644\u0623\u0641\u0636\u0644 \u0644\u0640<\/th><\/tr><\/thead><tbody><tr><td style=\"border:1px solid #ddd;padding:8px;\">1-9 \u0642\u0637\u0639<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0627\u0644\u062a\u0633\u0639\u064a\u0631 \u0627\u0644\u0642\u064a\u0627\u0633\u064a<\/td><td style=\"border:1px solid #ddd;padding:8px;\">3-5 \u0623\u064a\u0627\u0645<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Samples, prototypes<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">10-49 \u0642\u0637\u0639\u0629<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u062e\u0635\u0645 10%<\/td><td style=\"border:1px solid #ddd;padding:8px;\">5-7 \u0623\u064a\u0627\u0645<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Small production<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">50-99 pcs<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u062e\u0635\u0645 20%<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0645\u0646 7 \u0625\u0644\u0649 10 \u0623\u064a\u0627\u0645<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Medium production<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">100-499 \u0642\u0637\u0639\u0629<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u062e\u0635\u0645 30%<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0645\u0646 10 \u0625\u0644\u0649 15 \u064a\u0648\u0645\u0627\u064b<\/td><td style=\"border:1px solid #ddd;padding:8px;\">Large production (like Liquid Robotics order)<\/td><\/tr><tr><td style=\"border:1px solid #ddd;padding:8px;\">500+ pcs<\/td><td style=\"border:1px solid #ddd;padding:8px;\">35%+ discount<\/td><td style=\"border:1px solid #ddd;padding:8px;\">\u0645\u0646 15 \u0625\u0644\u0649 20 \u064a\u0648\u0645\u0627\u064b<\/td><td style=\"border:1px solid #ddd;padding:8px;\">High volume, OEM<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Example Order: 100 MCIL10M + 100 MCIL10F<\/h3>\n\n\n\n<p>Based on typical customer requirements (like Liquid Robotics):<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Order Specification<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Products:<\/strong> 100x MCIL10M (male) + 100x MCIL10F (female) = 100 pairs<\/li>\n<li><strong>Pin Count:<\/strong> 10 pins (gold-plated)<\/li>\n<li><strong>Housing:<\/strong> \u0641\u0648\u0644\u0627\u0630 \u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 316L<\/li>\n<li><strong>Depth Rating:<\/strong> 1000m (standard for ROV applications)<\/li>\n<li><strong>Termination:<\/strong> Solder cup (or crimp upon request)<\/li>\n<li><strong>Cable Entry:<\/strong> 6-12mm OD<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Pricing Breakdown<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Base Price:<\/strong> $XX.XX per piece (standard pricing)<\/li>\n<li><strong>Quantity:<\/strong> 200 pieces total (100 pairs)<\/li>\n<li><strong>Volume Discount:<\/strong> 30% off (100-499 piece tier)<\/li>\n<li><strong>Final Price:<\/strong> $XX.XX per piece<\/li>\n<li><strong>Total Order Value:<\/strong> $X,XXX.XX<\/li>\n<li><strong>\u0627\u0644\u0645\u0647\u0644\u0629 \u0627\u0644\u0632\u0645\u0646\u064a\u0629:<\/strong> \u0645\u0646 10 \u0625\u0644\u0649 15 \u064a\u0648\u0645\u0627\u064b<\/li>\n<li><strong>Shipping:<\/strong> DHL Express to USA (3-5 days)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Quality Testing<\/h3>\n\n\n\n<p>All MCIL10 connectors undergo comprehensive quality testing:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Standard Tests (Included)<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u2713 100% continuity testing (all 10 pins)<\/li>\n<li>\u2713 Insulation resistance (\u22651000 M\u03a9 @ 500V DC)<\/li>\n<li>\u2713 Hi-pot testing (1500V AC, 60 seconds)<\/li>\n<li>\u2713 Contact resistance (\u226410 m\u03a9 per pin)<\/li>\n<li>\u2713 Visual inspection (AQL 2.5)<\/li>\n<li>\u2713 Dimensional verification<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Optional Tests (Available)<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0636\u063a\u0637 (\u0645\u062d\u0627\u0643\u0627\u0629 \u0627\u0644\u0639\u0645\u0642)<\/li>\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0631\u0634 \u0627\u0644\u0645\u0644\u062d (\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u062a\u0622\u0643\u0644)<\/li>\n<li>Temperature cycling (-40\u00b0C to +85\u00b0C)<\/li>\n<li>Mating cycle testing (500+ cycles)<\/li>\n<li>Vibration testing (IEC 60068-2-6)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Compatible Products<\/h3>\n\n\n\n<p>MCIL10 connectors work with these HYSF products:<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Related Connectors<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>MCBH10M\/MCBH10F:<\/strong> Bulkhead version for panel mounting<\/li>\n<li><strong>MCIL8M\/MCIL8F:<\/strong> 8-pin inline (smaller size)<\/li>\n<li><strong>MCIL12M\/MCIL12F:<\/strong> 12-pin inline (higher pin count)<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Accessories<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Protective Caps:<\/strong> MCIL-CAP-M (male), MCIL-CAP-F (female)<\/li>\n<li><strong>Cable Glands:<\/strong> Various sizes for 6-12mm cable OD<\/li>\n<li><strong>Backshell Kits:<\/strong> Straight and angled options<\/li>\n<li><strong>Termination Tools:<\/strong> Crimping tools, solder jigs<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">How to Request a Quote<\/h3>\n\n\n\n<p>For MCIL10 connector quotations:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u0625\u0631\u0633\u0627\u0644 \u0627\u0633\u062a\u0641\u0633\u0627\u0631:<\/strong> Email info@hysfsubsea.com<\/li>\n<li><strong>Specify Requirements:<\/strong> MCIL10M\/MCIL10F, quantity, depth rating, termination type<\/li>\n<li><strong>Mention Application:<\/strong> ROV, sensors, etc. (helps with technical recommendations)<\/li>\n<li><strong>Request Volume Pricing:<\/strong> Specify if you need bulk order discount<\/li>\n<\/ol>\n\n\n\n<p><strong>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629:<\/strong> Complete quotation within 24-48 hours including volume discounts and freight options<\/p>\n\n\n\n<p><strong>\u0627\u062a\u0635\u0644 \u0628\u0640<\/strong> info@hysfsubsea.com<\/p>\n\n\n\n<p><em>Need MCIL 10-pin underwater connectors for your ROV or subsea project? Contact us with your specifications and we&#8217;ll provide competitive pricing with volume discounts within 24-48 hours.<\/em><\/p>","protected":false},"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"faq_category":[],"class_list":["post-4410","knowledge-base","type-knowledge-base","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/knowledge-base\/4410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/knowledge-base"}],"about":[{"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/types\/knowledge-base"}],"replies":[{"embeddable":true,"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/comments?post=4410"}],"version-history":[{"count":0,"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/knowledge-base\/4410\/revisions"}],"wp:attachment":[{"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/media?parent=4410"}],"wp:term":[{"taxonomy":"faq_category","embeddable":true,"href":"https:\/\/hysfsubsea.com\/ar\/wp-json\/wp\/v2\/faq_category?post=4410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}