{"id":1795,"date":"2026-01-23T01:59:30","date_gmt":"2026-01-23T01:59:30","guid":{"rendered":"https:\/\/hysfsubsea.com\/?post_type=product&#038;p=1795"},"modified":"2026-10-24T14:21:00","modified_gmt":"2026-10-24T14:21:00","slug":"bh10f-10-pin-female-bulkhead-subconn-compatible-underwater-connector","status":"publish","type":"product","link":"https:\/\/hysfsubsea.com\/ru\/product\/bh10f-10-pin-female-bulkhead-subconn-compatible-underwater-connector\/","title":{"rendered":"BH10F 10-Pin Female Bulkhead Underwater Connector \u2013 SubConn Compatible Stainless Steel Receptacle"},"content":{"rendered":"<h1>BH10F 10-Pin Female Bulkhead Underwater Connector \u2013 SubConn Compatible<\/h1>\n<h2>Product Overview<\/h2>\n<p>\u0421\u0430\u0439\u0442 <strong>HYSF SUBSEA BH10F<\/strong> is a high-performance <strong>10-pin female bulkhead underwater connector<\/strong> designed for reliable electrical connections through subsea pressure housings, underwater equipment enclosures, and marine instrument panels.<\/p>\n<p>As part of the HYSF Standard Circular Series, the BH10F features ten gold-plated female electrical contacts, a corrosion-resistant <strong>316L stainless steel housing<\/strong>, and a precision-engineered watertight sealing system.<\/p>\n<p>Designed for operating depths of up to <strong>6,000 meters (60 MPa)<\/strong>, the BH10F provides a dependable electrical interface between internal equipment electronics and external subsea cable assemblies.<\/p>\n<p>The connector supports an electrical rating of <strong>550V AC\/DC and 10A per contact<\/strong>, making it suitable for multi-channel signal transmission, electrical control circuits, underwater instrumentation, and appropriate power distribution applications.<\/p>\n<p>The standard BH10F configuration includes approximately <strong>0.3 meters of internal wire leads<\/strong> and a <strong>5\/8-18 UNF-2A mounting thread<\/strong> for installation in compatible underwater equipment housings.<\/p>\n<p>The BH10F is designed to mate with the <strong>IL10M 10-pin male inline underwater connector<\/strong> and is compatible with corresponding SubConn and SEACON Standard Circular connector interfaces.<\/p>\n<p>Typical applications include remotely operated vehicles (ROVs), autonomous underwater vehicles (AUVs), oceanographic instruments, subsea sensors, underwater camera systems, offshore monitoring equipment, and deep-sea research platforms.<\/p>\n<h2>Key Features and Benefits<\/h2>\n<h3>1. Ten Gold-Plated Female Electrical Contacts<\/h3>\n<p>The BH10F incorporates ten precision-manufactured female electrical contacts within a compact circular mating interface.<\/p>\n<p>Its ten-contact arrangement allows multiple electrical circuits to pass through a single bulkhead installation point.<\/p>\n<p>This configuration is suitable for applications involving:<\/p>\n<ul>\n<li>Multiple underwater sensor channels<\/li>\n<li>Electrical control signals<\/li>\n<li>Marine instrumentation<\/li>\n<li>Auxiliary power connections<\/li>\n<li>Subsea monitoring equipment<\/li>\n<li>Multi-core cable assemblies<\/li>\n<li>Underwater electronic modules<\/li>\n<\/ul>\n<p>Gold-plated contact surfaces help maintain reliable electrical conductivity and reduce contact-surface oxidation.<\/p>\n<p>The female contact configuration is designed to mate securely with the corresponding IL10M male inline connector.<\/p>\n<h3>2. Marine-Grade 316L Stainless Steel Housing<\/h3>\n<p>The standard BH10F features a precision-machined <strong>316L stainless steel housing<\/strong>, selected for demanding marine environments.<\/p>\n<p>316L stainless steel provides several advantages:<\/p>\n<ul>\n<li>Good resistance to seawater corrosion<\/li>\n<li>High mechanical strength<\/li>\n<li>Durability under external hydrostatic pressure<\/li>\n<li>Reliable threaded mounting<\/li>\n<li>Dimensional stability<\/li>\n<li>Suitability for deep-water equipment installations<\/li>\n<\/ul>\n<p>The metal housing provides mechanical support for the electrical contact assembly and allows the connector to be securely installed through compatible enclosure walls.<\/p>\n<p>When the BH10F is installed in an aluminum housing, galvanic corrosion protection should be evaluated as part of the overall equipment design.<\/p>\n<h3>3. Designed for 6,000-Meter Water Depth<\/h3>\n<p>The BH10F is designed to operate at external hydrostatic pressures of up to <strong>60 MPa<\/strong>, equivalent to approximately <strong>6,000 meters of seawater depth<\/strong>.<\/p>\n<p>Its watertight construction is intended to maintain electrical isolation between the external marine environment and internal equipment circuits.<\/p>\n<p>This deep-water capability makes the connector suitable for:<\/p>\n<ul>\n<li>Deep-sea scientific instruments<\/li>\n<li>Underwater robotic vehicles<\/li>\n<li>Offshore inspection equipment<\/li>\n<li>Oceanographic monitoring systems<\/li>\n<li>Marine exploration platforms<\/li>\n<li>Subsea electronic enclosures<\/li>\n<\/ul>\n<p>The complete installation must use the correct housing dimensions, sealing components, and assembly procedures to achieve the intended pressure performance.<\/p>\n<h3>4. SubConn and SEACON Compatible Interface<\/h3>\n<p>The HYSF BH10F is designed for compatibility with corresponding SubConn and SEACON Standard Circular underwater connector configurations.<\/p>\n<p>This compatibility makes it a practical option for customers requiring:<\/p>\n<ul>\n<li>Replacement underwater bulkhead connectors<\/li>\n<li>Compatible subsea cable interfaces<\/li>\n<li>Marine equipment maintenance<\/li>\n<li>Underwater system upgrades<\/li>\n<li>OEM subsea instrumentation<\/li>\n<li>Standardized electrical connections<\/li>\n<\/ul>\n<p>For replacement applications, customers should verify the connector series, contact arrangement, mating gender, and installation dimensions before selecting the BH10F.<\/p>\n<h3>5. Wet-Mateable Underwater Connection<\/h3>\n<p>The BH10F belongs to HYSF SUBSEA&#8217;s wet-mateable Standard Circular connector family.<\/p>\n<p>When paired with the corresponding IL10M male inline connector, the interface is designed to support underwater mating and unmating.<\/p>\n<p>This capability is useful for subsea equipment that requires periodic maintenance, cable replacement, or modular system integration.<\/p>\n<p><strong>Important:<\/strong> Electrical power should normally be disconnected before mating or unmating unless the complete connector assembly has been specifically qualified for energized operation.<\/p>\n<h3>6. Precision 5\/8-18 UNF-2A Mounting Thread<\/h3>\n<p>The BH10F uses a <strong>5\/8-18 UNF-2A mounting thread<\/strong> for secure installation in compatible underwater equipment housings.<\/p>\n<p>The standard mounting configuration includes:<\/p>\n<ul>\n<li><strong>Mounting Thread:<\/strong> 5\/8-18 UNF-2A<\/li>\n<li><strong>Nominal Thread Length:<\/strong> 19 mm<\/li>\n<li><strong>Installation Type:<\/strong> Threaded Bulkhead<\/li>\n<li><strong>Standard Housing Material:<\/strong> \u041d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c 316L<\/li>\n<\/ul>\n<p>The threaded design supports secure panel mounting and accurate positioning of the connector within an enclosure.<\/p>\n<p>Before machining the equipment housing, the mounting hole dimensions, wall thickness, sealing surface, and installation clearance should be verified using the approved mechanical drawing.<\/p>\n<h3>7. Watertight O-Ring Sealing<\/h3>\n<p>The BH10F incorporates a bulkhead sealing arrangement designed to prevent seawater ingress through the connector mounting interface.<\/p>\n<p>O-ring sealing provides a barrier between the connector housing and the equipment panel.<\/p>\n<p>Proper sealing performance depends on:<\/p>\n<ul>\n<li>Correct O-ring dimensions<\/li>\n<li>Suitable sealing material<\/li>\n<li>Proper groove geometry<\/li>\n<li>Clean sealing surfaces<\/li>\n<li>Appropriate O-ring compression<\/li>\n<li>Correct installation procedures<\/li>\n<\/ul>\n<p>Depending on the selected configuration, customized sealing arrangements may be available.<\/p>\n<p>For high-pressure equipment, the complete housing and bulkhead assembly should be validated under the intended operating conditions.<\/p>\n<h3>8. Standard 0.3-Meter Internal Wire Leads<\/h3>\n<p>The BH10F is normally supplied with approximately <strong>0.3 meters of internal wire leads<\/strong>.<\/p>\n<p>These leads allow the bulkhead connector to be electrically connected to equipment inside the pressure housing.<\/p>\n<p>The standard pigtail arrangement simplifies integration into underwater electronic modules, marine instrumentation, and control systems.<\/p>\n<p>Available customization options may include:<\/p>\n<ul>\n<li>Longer internal wire leads<\/li>\n<li>Different conductor specifications<\/li>\n<li>Customized pin assignments<\/li>\n<li>Numbered wire identification<\/li>\n<li>Application-specific terminations<\/li>\n<li>OEM bulkhead connector assemblies<\/li>\n<\/ul>\n<p>The actual wiring arrangement should always be confirmed against the supplied wiring diagram.<\/p>\n<h3>9. Optional Anodized Aluminum Housing<\/h3>\n<p>In addition to the standard 316L stainless steel construction, the BH10F may be supplied with an anodized aluminum housing.<\/p>\n<p>Aluminum configurations may be useful for underwater equipment requiring reduced weight or improved material compatibility with aluminum pressure housings.<\/p>\n<p>Material selection should consider:<\/p>\n<ul>\n<li>Operating depth<\/li>\n<li>Equipment weight requirements<\/li>\n<li>Corrosion protection<\/li>\n<li>Housing compatibility<\/li>\n<li>Mechanical strength<\/li>\n<li>Surface treatment<\/li>\n<li>Long-term seawater exposure<\/li>\n<\/ul>\n<p>Custom housing materials and sealing arrangements are subject to technical review.<\/p>\n<h2>BH10F Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/th>\n<\/tr>\n<tr>\n<td>Brand<\/td>\n<td>HYSF SUBSEA<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>BH10F<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0435\u0440\u0438\u044f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432<\/td>\n<td>Standard Circular<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u0440\u0430\u0437\u044a\u0435\u043c\u0430<\/td>\n<td>\u041d\u0430\u043a\u043b\u0430\u0434\u043d\u0430\u044f \u0440\u043e\u0437\u0435\u0442\u043a\u0430<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0432<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Contact Gender<\/td>\n<td>Female<\/td>\n<\/tr>\n<tr>\n<td>Contact Finish<\/td>\n<td>Gold-Plated<\/td>\n<\/tr>\n<tr>\n<td>Standard Housing Material<\/td>\n<td>\u041d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c 316L<\/td>\n<\/tr>\n<tr>\n<td>Optional Housing Material<\/td>\n<td>Anodized Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Mounting Style<\/td>\n<td>Threaded Bulkhead<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u043d\u0442\u0430\u0436\u043d\u0430\u044f \u0440\u0435\u0437\u044c\u0431\u0430<\/td>\n<td>5\/8-18 UNF-2A<\/td>\n<\/tr>\n<tr>\n<td>Nominal Thread Length<\/td>\n<td>19 mm<\/td>\n<\/tr>\n<tr>\n<td>Rated Voltage<\/td>\n<td>550V AC\/DC<\/td>\n<\/tr>\n<tr>\n<td>Rated Current<\/td>\n<td>10A per Contact<\/td>\n<\/tr>\n<tr>\n<td>Maximum Operating Depth<\/td>\n<td>6,000 m<\/td>\n<\/tr>\n<tr>\n<td>Pressure Rating<\/td>\n<td>60 MPa<\/td>\n<\/tr>\n<tr>\n<td>Mating Capability<\/td>\n<td>Wet-Mateable<\/td>\n<\/tr>\n<tr>\n<td>Standard Internal Wire Length<\/td>\n<td>0.3 m<\/td>\n<\/tr>\n<tr>\n<td>Custom Wire Lengths<\/td>\n<td>Available<\/td>\n<\/tr>\n<tr>\n<td>Sealing System<\/td>\n<td>O-Ring Sealing<\/td>\n<\/tr>\n<tr>\n<td>Mating Inline Connector<\/td>\n<td>IL10M<\/td>\n<\/tr>\n<tr>\n<td>Protective Dummy Connector<\/td>\n<td>DC10M<\/td>\n<\/tr>\n<tr>\n<td>SubConn Compatibility<\/td>\n<td>Corresponding Standard Circular Interfaces<\/td>\n<\/tr>\n<tr>\n<td>SEACON Compatibility<\/td>\n<td>Corresponding Standard Circular Interfaces<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>12 Months<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Note:<\/strong> Customized housing materials, thread lengths, and sealing configurations may require different mechanical dimensions. Always verify the approved technical drawing before machining the equipment housing.<\/p>\n<h2>Standard 10-Pin Wiring Reference<\/h2>\n<p>The HYSF SUBSEA Standard Circular 10-pin series uses the following standard cable wire colors:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Pin Number<\/th>\n<th>Wire Color<\/th>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Red<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>Red\/White<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Black<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Black\/White<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Yellow<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Yellow\/White<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Blue<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Blue\/White<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>Orange<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Orange\/White<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This table represents the standard cable wiring reference for the 10-pin Standard Circular Series.<\/p>\n<p><strong>Important:<\/strong> Bulkhead connectors may be supplied with numbered internal leads or alternative wire identification arrangements. The actual pin-to-wire mapping should be verified against the corresponding wiring diagram.<\/p>\n<h2>Compatible Mating Connectors and Accessories<\/h2>\n<h3>IL10M \u2013 10-Pin Male Inline Underwater Connector<\/h3>\n<p>\u0421\u0430\u0439\u0442 <strong>IL10M<\/strong> is the standard mating connector for the BH10F female bulkhead receptacle.<\/p>\n<p>Typical IL10M characteristics include:<\/p>\n<ul>\n<li>Ten male electrical contacts<\/li>\n<li>Molded neoprene rubber body<\/li>\n<li>Gold-plated electrical contacts<\/li>\n<li>Standard 1-meter underwater cable<\/li>\n<li>Wet-mateable construction<\/li>\n<li>6,000-meter depth rating<\/li>\n<\/ul>\n<p>When mated, the IL10M and BH10F provide a detachable electrical connection between the external underwater cable and the equipment electronics inside the pressure housing.<\/p>\n<h3>DC10M \u2013 10-Pin Male Dummy Plug<\/h3>\n<p>\u0421\u0430\u0439\u0442 <strong>DC10M<\/strong> is the corresponding male protective dummy connector for the BH10F female bulkhead interface.<\/p>\n<p>When the IL10M cable connector is disconnected, the DC10M can be installed to help protect the exposed mating interface.<\/p>\n<p>The dummy plug helps reduce contamination and accidental mechanical damage during equipment storage, maintenance, and suitable underwater operations.<\/p>\n<p>The DC10M is a protective accessory and does not provide an electrical connection.<\/p>\n<h3>BH10M \u2013 10-Pin Male Bulkhead Connector<\/h3>\n<p>\u0421\u0430\u0439\u0442 <strong>BH10M<\/strong> is the male-contact version of the Standard Circular 10-pin bulkhead connector.<\/p>\n<p>The standard mating relationships are:<\/p>\n<ul>\n<li><strong>BH10F mates with IL10M.<\/strong><\/li>\n<li><strong>BH10M mates with IL10F.<\/strong><\/li>\n<\/ul>\n<p>Both bulkhead configurations belong to the same Standard Circular connector family.<\/p>\n<h2>\u0422\u0438\u043f\u043e\u0432\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h2>\n<h3>Remotely Operated Vehicles (ROVs)<\/h3>\n<p>ROVs often require multiple electrical connections through sealed pressure housings.<\/p>\n<p>The BH10F can be installed in underwater electronics enclosures to support suitable connections involving:<\/p>\n<ul>\n<li>External sensors<\/li>\n<li>Camera systems<\/li>\n<li>Control electronics<\/li>\n<li>Monitoring equipment<\/li>\n<li>Auxiliary instrumentation<\/li>\n<\/ul>\n<p>Its ten-contact arrangement allows multiple circuits to pass through one bulkhead interface.<\/p>\n<h3>Autonomous Underwater Vehicles (AUVs)<\/h3>\n<p>AUVs frequently contain multiple electronic modules and external instruments.<\/p>\n<p>The BH10F provides a panel-mounted electrical interface for suitable power, signal, and control circuits.<\/p>\n<p>Its detachable mating design can simplify equipment maintenance and cable replacement.<\/p>\n<h3>Underwater Camera Housings<\/h3>\n<p>Underwater camera systems require reliable electrical connections between external cables and sealed camera enclosures.<\/p>\n<p>The BH10F can provide a watertight bulkhead interface for appropriate electrical circuits.<\/p>\n<p>Compatibility with specific video or Ethernet protocols depends on the cable construction, conductor pairing, and complete system design.<\/p>\n<h3>Oceanographic Instrumentation<\/h3>\n<p>The BH10F is suitable for applications involving:<\/p>\n<ul>\n<li>CTD-related instruments<\/li>\n<li>Marine environmental sensors<\/li>\n<li>Oceanographic monitoring systems<\/li>\n<li>Underwater acoustic equipment<\/li>\n<li>Scientific data acquisition devices<\/li>\n<li>Seabed observation platforms<\/li>\n<\/ul>\n<p>Its ten-contact arrangement provides additional wiring capacity for instruments requiring multiple electrical channels.<\/p>\n<h3>Offshore Inspection Equipment<\/h3>\n<p>Offshore systems frequently operate in environments involving seawater exposure, high hydrostatic pressure, and mechanical stress.<\/p>\n<p>The BH10F can be integrated into subsea electronic housings used for monitoring, inspection, and instrumentation.<\/p>\n<h3>Marine Research Platforms<\/h3>\n<p>Research organizations and subsea equipment manufacturers may require customized bulkhead electrical connections for specialized instruments.<\/p>\n<p>The BH10F offers a standardized ten-contact interface suitable for integration into compatible pressure housings and marine electronic systems.<\/p>\n<h2>Installation Guidelines<\/h2>\n<p>Correct installation is essential for maintaining watertight performance.<\/p>\n<h3>Step 1: Confirm Mounting Dimensions<\/h3>\n<p>Verify the 5\/8-18 UNF-2A mounting thread and the required panel opening dimensions.<\/p>\n<p>Check the available installation space and housing wall thickness.<\/p>\n<h3>Step 2: Inspect the Connector<\/h3>\n<p>Examine the housing, electrical contacts, and sealing surfaces for scratches, damage, or contamination.<\/p>\n<h3>Step 3: Prepare the Mounting Surface<\/h3>\n<p>Ensure the equipment housing has been machined according to the approved technical drawing.<\/p>\n<p>Remove sharp edges, metal particles, and other contaminants.<\/p>\n<h3>Step 4: Inspect the O-Ring<\/h3>\n<p>Check the sealing component for damage, deformation, or contamination.<\/p>\n<p>Use the correct O-ring specification and follow the appropriate installation instructions.<\/p>\n<h3>Step 5: Install the BH10F<\/h3>\n<p>Position the connector in the equipment housing and secure it using the specified mounting arrangement.<\/p>\n<p>Avoid excessive mechanical stress or overtightening.<\/p>\n<h3>Step 6: Connect the Internal Wiring<\/h3>\n<p>Connect the internal wire leads according to the approved wiring diagram.<\/p>\n<p>Verify the pin assignments before applying electrical power.<\/p>\n<h3>Step 7: Mate the IL10M Connector<\/h3>\n<p>Inspect the mating surfaces and align the IL10M correctly with the BH10F.<\/p>\n<p>Follow the recommended mating procedure and avoid excessive insertion force.<\/p>\n<h3>Step 8: Perform Final Testing<\/h3>\n<p>Verify electrical continuity and insulation performance.<\/p>\n<p>Where required, conduct hydrostatic pressure testing of the complete enclosure assembly before deployment.<\/p>\n<h2>Quality Control and Testing<\/h2>\n<p>HYSF SUBSEA supports underwater connector manufacturing through quality-control procedures such as:<\/p>\n<ul>\n<li>Hydrostatic pressure testing<\/li>\n<li>Electrical continuity testing<\/li>\n<li>Insulation resistance measurement<\/li>\n<li>Dielectric withstand testing<\/li>\n<li>Contact inspection<\/li>\n<li>Dimensional verification<\/li>\n<li>O-ring sealing inspection<\/li>\n<li>Mechanical integrity checks<\/li>\n<\/ul>\n<p>Additional testing and documentation can be specified according to project requirements.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Q1: What is BH10F?<\/h3>\n<p>BH10F is a ten-contact female bulkhead underwater electrical connector in the HYSF Standard Circular Series.<\/p>\n<h3>Q2: Which inline connector mates with BH10F?<\/h3>\n<p>The standard mating connector is the <strong>IL10M 10-pin male inline underwater connector<\/strong>.<\/p>\n<h3>Q3: Is BH10F compatible with SubConn connectors?<\/h3>\n<p>Yes. BH10F is designed for compatibility with corresponding SubConn Standard Circular underwater connector configurations.<\/p>\n<h3>Q4: What is the mounting thread size?<\/h3>\n<p>The standard mounting thread is <strong>5\/8-18 UNF-2A<\/strong>.<\/p>\n<h3>Q5: What is the housing material?<\/h3>\n<p>The standard housing is manufactured from <strong>316L stainless steel<\/strong>. Anodized aluminum versions may also be available.<\/p>\n<h3>Q6: What is the maximum operating depth?<\/h3>\n<p>The BH10F is designed for underwater depths of up to <strong>6 000 \u043c\u0435\u0442\u0440\u043e\u0432<\/strong>, equivalent to approximately 60 MPa.<\/p>\n<h3>Q7: What are the electrical ratings?<\/h3>\n<p>The connector is rated for <strong>550V AC\/DC and 10A per contact<\/strong>.<\/p>\n<h3>Q8: What is the standard internal wire length?<\/h3>\n<p>The standard internal wire lead length is approximately <strong>0.3 meters<\/strong>.<\/p>\n<h3>Q9: Can BH10F be connected underwater?<\/h3>\n<p>Yes. BH10F belongs to the wet-mateable Standard Circular Series. Electrical power should normally be disconnected before mating or unmating.<\/p>\n<h3>Q10: Does BH10F require O-ring sealing?<\/h3>\n<p>Yes. The bulkhead installation uses an O-ring sealing arrangement to help maintain watertight integrity.<\/p>\n<h3>Q11: Which dummy connector protects BH10F?<\/h3>\n<p>The corresponding protective accessory is the <strong>DC10M male dummy plug<\/strong>.<\/p>\n<h3>Q12: Is BH10F the same as MCBH10F?<\/h3>\n<p>No. BH10F belongs to the Standard Circular Series, while MCBH10F belongs to the Micro Circular Series. Their mating interfaces and mounting dimensions are different.<\/p>\n<h3>Q13: Can the internal wire length be customized?<\/h3>\n<p>Yes. Alternative internal wire lengths and termination arrangements can be manufactured according to project requirements.<\/p>\n<h3>Q14: Can BH10F be installed in an aluminum housing?<\/h3>\n<p>Yes, provided the installation dimensions and sealing arrangement are suitable. Galvanic corrosion protection should be considered when stainless steel and aluminum components are exposed to seawater.<\/p>\n<h2>Why Choose HYSF SUBSEA?<\/h2>\n<p>HYSF SUBSEA specializes in underwater electrical connectors, bulkhead connectors, marine cable assemblies, and customized subsea interconnection solutions.<\/p>\n<p>Our manufacturing capabilities include:<\/p>\n<ul>\n<li>SubConn-compatible underwater connector production<\/li>\n<li>Precision-machined stainless steel bulkhead housings<\/li>\n<li>Standard and custom underwater cable assemblies<\/li>\n<li>Deep-water pressure testing<\/li>\n<li>OEM and ODM engineering support<\/li>\n<li>Mechanical drawings and 3D models<\/li>\n<li>Customized wiring and termination solutions<\/li>\n<li>Underwater connector accessories<\/li>\n<li>12-month product warranty<\/li>\n<\/ul>\n<p>\u0421\u0430\u0439\u0442 <strong>BH10F 10-pin female bulkhead underwater connector<\/strong> provides a durable electrical interface for marine equipment requiring multiple circuits, reliable pressure-resistant sealing, and compatibility with established subsea connector systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0421\u0430\u0439\u0442 <strong>HYSF SUBSEA BH10F<\/strong> is a high-performance <strong>10-pin female bulkhead underwater connector<\/strong> designed for reliable electrical connections through subsea pressure housings, marine equipment enclosures, and underwater instrument panels.<\/p>\n<p>Manufactured with a corrosion-resistant <strong>316L stainless steel housing<\/strong> and ten gold-plated female electrical contacts, the BH10F provides a durable watertight interface for deep-sea applications.<\/p>\n<p>Designed to withstand operating pressures of up to <strong>60 MPa (6,000 meters underwater)<\/strong>, the connector supports a rated voltage of <strong>550V AC\/DC<\/strong> and a rated current of <strong>10A per contact<\/strong>.<\/p>\n<p>The BH10F features a <strong>5\/8-18 UNF-2A mounting thread<\/strong>, an O-ring sealing arrangement, and standard <strong>0.3-meter internal wire leads<\/strong> for integration into sealed electronic equipment.<\/p>\n<p><strong>Key Specifications:<\/strong><\/p>\n<ul>\n<li><strong>Model:<\/strong> BH10F<\/li>\n<li><strong>Connector Type:<\/strong> 10-Pin Female Bulkhead Receptacle<\/li>\n<li><strong>Series:<\/strong> Standard Circular<\/li>\n<li><strong>Number of Contacts:<\/strong> 10<\/li>\n<li><strong>Contact Gender:<\/strong> Female<\/li>\n<li><strong>Standard Housing Material:<\/strong> \u041d\u0435\u0440\u0436\u0430\u0432\u0435\u044e\u0449\u0430\u044f \u0441\u0442\u0430\u043b\u044c 316L<\/li>\n<li><strong>Optional Housing:<\/strong> Anodized Aluminum<\/li>\n<li><strong>Contact Finish:<\/strong> Gold-Plated<\/li>\n<li><strong>Mounting Thread:<\/strong> 5\/8-18 UNF-2A<\/li>\n<li><strong>Nominal Thread Length:<\/strong> 19 mm<\/li>\n<li><strong>Operating Depth:<\/strong> Up to 6,000 m<\/li>\n<li><strong>Pressure Rating:<\/strong> 60 MPa<\/li>\n<li><strong>Rated Voltage:<\/strong> 550V AC\/DC<\/li>\n<li><strong>Rated Current:<\/strong> 10A per Contact<\/li>\n<li><strong>Standard Internal Wire Length:<\/strong> 0.3 m<\/li>\n<li><strong>Sealing System:<\/strong> O-Ring Sealing<\/li>\n<li><strong>Mating Connector:<\/strong> IL10M Male Inline Connector<\/li>\n<li><strong>Protective Accessory:<\/strong> DC10M Male Dummy Plug<\/li>\n<li><strong>Compatibility:<\/strong> Corresponding SubConn and SEACON Standard Circular Interfaces<\/li>\n<li><strong>Mating Capability:<\/strong> Wet-Mateable<\/li>\n<li><strong>\u0413\u0430\u0440\u0430\u043d\u0442\u0438\u044f:<\/strong> 12 Months<\/li>\n<\/ul>\n<p>The BH10F is suitable for <strong>ROVs, AUVs, underwater cameras, oceanographic instruments, marine sensors, offshore monitoring equipment, and deep-sea research systems<\/strong>.<\/p>\n<p>Customized internal wire lengths, conductor configurations, anodized aluminum housings, and specialized sealing arrangements may be available according to project requirements.<\/p>","protected":false},"featured_media":9105,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[30],"product_cat":[32],"product_tag":[],"class_list":["post-1795","product","type-product","status-publish","has-post-thumbnail","product_brand-hysf","product_cat-standard-circular-connectors","pa_body-material-316l-stainless-steel","pa_connector-type-bulkhead-receptacle","pa_electrical-rating-550v-10a","pa_mounting-thread-5-8-18-unf","pa_number-of-contacts-10-pin","pa_series-standard-series","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product\/1795","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/comments?post=1795"}],"version-history":[{"count":3,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product\/1795\/revisions"}],"predecessor-version":[{"id":9340,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product\/1795\/revisions\/9340"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/media\/9105"}],"wp:attachment":[{"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/media?parent=1795"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1795"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1795"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hysfsubsea.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1795"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}