Hurtigt svar
HYSF performs comprehensive testing on all underwater connectors including:
- Pressure testing: 1.5x rated depth for 24 hours
- Electrical testing: Continuity, insulation resistance, hipot
- Environmental testing: Salt spray, temperature cycling, UV exposure
- Mechanical testing: Mating cycles, vibration, pull test
- Leak detection: Helium mass spectrometry for critical applications
Every connector ships with test certificates documenting all results.
Factory Acceptance Testing (Every Unit)
Pressure Testing
| Test | Parameters | Acceptance Criteria |
|---|---|---|
| Static pressure | 1.5x rated pressure, 24 hours | No leakage, no deformation |
| Pressure cycling | 0 to rated pressure, 100 cycles | No leakage, stable resistance |
| Decompression | Rapid decompression from rated depth | No seal failure, no damage |
Electrical Testing
| Test | Parameters | Acceptance Criteria |
|---|---|---|
| Continuity | Each contact pair | <10 mΩ resistance |
| Isolationsmodstand | 500V DC, contact to housing | >1000 MΩ |
| Hipot (Dielectric) | 1500V AC, 60 seconds | No breakdown, no flashover |
| Contact resistance stability | After pressure test | <5% change from initial |
Visual Inspection
- Dimensional verification per drawing
- Surface finish inspection
- Marking and labeling verification
- O-ring and seal inspection
- Thread inspection (go/no-go gauges)
Environmental Testing (Sample/Type Testing)
Corrosion Testing
| Test | Standard | Duration | Criteria |
|---|---|---|---|
| Salt spray (fog) | ASTM B117 | 500-1000 hours | No red corrosion, ≤5% surface affected |
| Immersion | ASTM G31 | 30 days seawater | No pitting, no cracking |
| CASS test | ASTM B368 | 240 hours | Coating adhesion maintained |
Temperature Testing
| Test | Parameters | Cycles | Criteria |
|---|---|---|---|
| Thermal cycling | -40°C to +85°C | 50 cycles | No cracking, stable electrical |
| Thermal shock | -55°C to +125°C, 5 min transfer | 10 cycles | No damage, no leakage |
| Low temperature | -40°C, 24 hours | Static | No brittleness, seals functional |
| High temperature | +85°C, 24 hours | Static | No deformation, seals functional |
UV and Weathering
| Test | Standard | Duration | Criteria |
|---|---|---|---|
| UV exposure | ASTM G154 | 1000 hours | No cracking, color change ≤3 ΔE |
| Weatherometer | ASTM G155 | 2000 hours | No degradation of properties |
Mechanical Testing
Mating Cycle Testing
| Type stik | Cycles | Frekvens | Criteria |
|---|---|---|---|
| Dry mate | 500 cycles | Type test | <10% resistance change, no damage |
| Wet mate | 200 cycles | Type test | No leakage, smooth operation |
| Production sample | 50 cycles | Per lot | Functional verification |
Vibration Testing
| Test | Standard | Parameters | Criteria |
|---|---|---|---|
| Sine vibration | MIL-STD-810 | 10-2000 Hz, 10G | No discontinuity >1μs |
| Random vibration | MIL-STD-810 | 20-2000 Hz, 7.7 Grms | No physical damage |
| Shock | MIL-STD-810 | 100G, 11ms half-sine | No damage, functional |
Cable and Strain Relief
| Test | Parameters | Criteria |
|---|---|---|
| Pull test | 50 lbs (222N), 1 minute | No movement, no damage |
| Bend test | 10x cable diameter, 180° | No damage at entry |
| Torsion test | ±90°, 100 cycles | No degradation |
Advanced Testing (Optional/Custom)
Helium Leak Detection
- Sensitivity: 1×10⁻⁹ mbar·L/s
- Application: Critical deep-sea, military, nuclear
- Standard: MIL-STD-883 or custom
EMC/EMI Testing
- Electromagnetic interference susceptibility
- Radio frequency interference testing
- Electrostatic discharge (ESD) testing
- Available through certified partner labs
Material Analysis
- XRF material verification
- Hardness testing
- Metallographic examination
- Coating thickness measurement
Certification and Documentation
Standard Documentation (Included)
- ✓ Certificate of Conformance (CoC)
- ✓ Pressure test report
- ✓ Electrical test report
- ✓ Material certificates (on request)
- ✓ Dimensional inspection report
Optional Documentation
- Third-party inspection reports
- Class approval certificates (DNV, ABS, LR)
- Full material traceability
- Environmental test reports
- Custom test protocols
Testing Facilities
HYSF operates in-house testing facilities including:
- Hyperbaric pressure chambers (up to 600 bar)
- Electrical test stations
- Environmental chambers
- Salt spray cabinets
- Mechanical test equipment
Specialized testing is conducted through ISO 17025 accredited partner laboratories.
Quality Standards
- ISO 9001:2015 certified manufacturing
- Testing per MIL-DTL-24308, MIL-STD-810, or customer specifications
- Full traceability from raw materials to finished product
- Calibrated equipment with NIST-traceable standards
Kontakt os
Testing inquiries: quality@hysfsubsea.com
Teknisk support: tech@hysfsubsea.com
Certification requests: certs@hysfsubsea.com