How do I match connectors to my existing cables?

Raskt svar: Cable matching is critical for reliable connections. Key factors: Cable outer diameter (must fit connector), number of conductors (must match connector pins), conductor size (must handle your current), jacket material (must suit your environment). We offer cable assembly service – send us your cable specs or samples and we’ll match the right connector. Popular cable types: Polyurethane (flexible, ROV), TPE (general purpose), Polyethylene (deep water). Tell us your cable OD and we’ll recommend compatible connectors.

Cable-Connector Matching Guide

Key Matching Factors

1. Cable Outer Diameter (OD)

Most critical dimension! Connector must grip cable properly.

Cable OD RangeCompatible Connector SeriesGland Size
4-6mmMCM miniature seriesSmall
6-10mmMCBH 2-6 pinMedium
10-14mmMCBH 8-12 pinLarge
14-20mmMCBH 14-24 pinExtra Large
20mm+Custom connectorsCustom

2. Number of Conductors

Must match connector pin count (or use fewer pins than available).

  • 2 conductors → 2-pin connector (or larger)
  • 4 conductors → 4-pin connector (or larger)
  • Cannot use 6-conductor cable with 4-pin connector (waste)
  • Can use 4-conductor cable with 6-pin connector (2 pins unused)

3. Conductor Size (Wire Gauge)

Must handle your current without overheating.

Wire Gauge (AWG)Max CurrentBest for
22 AWG3ASignal, low power
20 AWG5ASignal, sensors
18 AWG10AControl, medium power
16 AWG15APower, thrusters (small)
14 AWG20APower, thrusters (medium)
12 AWG30AHigh power
10 AWG40AVery high power

4. Jacket Material

Must suit your environment.

Jacket MaterialBest forTemperaturFlexibility
Polyuretan (PUR)ROV, high flex-40°C to +80°CUtmerket
TPEGenerelt om marine-30°C to +70°CMeget bra
Polyethylene (PE)Deep water, static-50°C to +60°CBra
PVCFreshwater, budget-15°C to +60°CRimelig
NeopreneOil & gas-40°C to +90°CBra

Cable Assembly Service

Don’t want to match yourself? We’ll do it for you!

Option 1: Send Us Your Cable

  1. Ship 1-2 meters of your cable to us
  2. We measure and identify specifications
  3. We recommend compatible connectors
  4. We can assemble connectors for you

Option 2: Tell Us Your Specs

Email us:

  • Cable outer diameter (mm)
  • Number of conductors
  • Conductor size (AWG or mm²)
  • Jacket material (if known)
  • Application (ROV, sensor, etc.)

We’ll recommend the right connector.

Option 3: Buy Complete Assembly

We sell pre-assembled cable assemblies:

  • Connector already attached
  • Pressure tested
  • Ready to use
  • Custom lengths available

Popular Cable Types for Underwater Use

ROV Tether Cable

  • Construction: Multiple conductors + strength members
  • Jacket: Polyurethane (high flex, abrasion resistant)
  • OD: Typically 8-15mm
  • Connector: MCBH series with appropriate gland

Sensor Cable

  • Construction: 2-8 conductors, often shielded
  • Jacket: TPE or polyurethane
  • OD: Typically 4-8mm
  • Connector: MCM or MCBH series

Power Cable

  • Construction: 2-4 large conductors
  • Jacket: Neoprene or polyurethane
  • OD: Typically 10-20mm
  • Connector: High-current MCBH series

Ethernet Cable (Underwater)

  • Construction: 4 twisted pairs + drain wire
  • Jacket: Polyurethane
  • OD: Typically 6-10mm
  • Connector: Ethernet-compatible underwater connector

Cable Preparation Tips

For Connector Installation

  1. Strip outer jacket: Carefully, don’t nick conductors
  2. Prepare conductors: Strip to correct length
  3. Tin conductors: Solder tip for easier insertion
  4. Insert into connector: Follow pinout diagram
  5. Pot/seal: Use epoxy or potting compound
  6. Assemble connector: Follow torque specifications

Common Mistakes to Avoid

  • ❌ Cable OD too small (won’t seal properly)
  • ❌ Cable OD too large (won’t fit in connector)
  • ❌ Conductors too large for contacts
  • ❌ Wrong stripping length
  • ❌ Damaged conductor insulation
  • ❌ Inadequate potting/sealing

Need Help?

Cable matching can be tricky. We’re here to help:

  • 📧 Email: sales@hysfsubsea.com
  • 📎 Attach: Cable spec sheet or photo
  • 📏 Include: Cable OD measurement (most important!)
  • ⚡ Specify: Current/voltage requirements

Related: Tekniske spesifikasjoner | Cable Assemblies

Need cable matching help? Email sales@hysfsubsea.com with your cable details.

Bilde av John Zhang

John Zhang

(administrerende direktør og ledende ingeniør)
E-post: info@hysfsubsea.com
Jeg har over 15 års erfaring med undervannskoblingsteknologi og leder HYSFs FoU-team som utformer høytrykksløsninger (60 MPa). Jeg fokuserer på å sikre pålitelighet uten lekkasje for ROV-er, AUV-er og offshore-instrumentering. Jeg fører personlig tilsyn med valideringen av våre tilpassede prototyper.

Har du et komplisert teknisk spørsmål?

Utprøvde løsninger i felten

Et utstillingsvindu for vårt vellykkede samarbeid med globale partnere innen marin robotikk, energi og forskning. Hvert prosjekt gjenspeiler vår forpliktelse til null lekkasjeintegritet og driftssikkerhet.

Start ditt subseaprosjekt med HYSF

Enten du trenger et raskt tilbud på standardkontakter eller en kompleks, spesialtilpasset kabelmontering, står ingeniørteamet vårt klart til å hjelpe deg. Du kan forvente et teknisk svar innen 12 timer.

John Zhang

ADMINISTRERENDE DIREKTØR

Jason Liu
Kevin Wang
Cindy Chen
Lily Li
Demo av kontaktskjema