What specific testing procedures do HYSF products undergo?

Quality assurance at HYSF is rigorous. Our pre-shipment testing includes Hydrostatic Pressure Testing (up to 100MPa pumps for 60 minutes), Dielectric Withstand (Hipot) Testing (1000V), Insulation Resistance (IR) Testing (>200MΩ), and Dynamic Continuity Testing to ensure zero failure under real-world conditions.

We don’t just “spot check.” HYSF utilizes a comprehensive, precision-driven testing system. Here is the exact protocol every batch is subjected to, as detailed in our quality standards:

  1. Hydrostatic Pressure Test:
    • Equipment: 100MPa High-Pressure Pump.
    • Procedure: Connectors are sealed in a pressure vessel filled with water. We pressurize it to the target level (e.g., 60MPa for deep-sea series) and hold it for 60 minutes.
    • Pass Criteria: Zero leakage and no structural deformation.
  2. Insulation Resistance (IR) Test:
    • Standard: We apply 1000V across all contacts and the housing.
    • Pass Criteria: Resistance must exceed 200MΩ. This ensures no short circuits even in high-humidity environments.
  3. Dielectric Withstand (Hipot) Test:
    • Procedure: 1000V AC/DC is applied between pins and the shell to verify insulation integrity.
    • Pass Criteria: Leakage current must be < 10mA.
  4. Dynamic Continuity Test (“Shake Test”):
    • Procedure: We monitor real-time resistance while vigorously shaking and bending the cable assembly.
    • Purpose: To ensure internal wiring connections are robust and won’t fail during dynamic ROV movements.
Bilde av John Zhang

John Zhang

(administrerende direktør og ledende ingeniør)
E-post: [email protected]
Jeg har over 15 års erfaring med undervannskoblingsteknologi og leder HYSFs FoU-team som utformer høytrykksløsninger (60 MPa). Jeg fokuserer på å sikre pålitelighet uten lekkasje for ROV-er, AUV-er og offshore-instrumentering. Jeg fører personlig tilsyn med valideringen av våre tilpassede prototyper.

Har du et komplisert teknisk spørsmål?

Utprøvde løsninger i felten

Et utstillingsvindu for vårt vellykkede samarbeid med globale partnere innen marin robotikk, energi og forskning. Hvert prosjekt gjenspeiler vår forpliktelse til null lekkasjeintegritet og driftssikkerhet.

Start ditt subseaprosjekt med HYSF

Enten du trenger et raskt tilbud på standardkontakter eller en kompleks, spesialtilpasset kabelmontering, står ingeniørteamet vårt klart til å hjelpe deg. Du kan forvente et teknisk svar innen 12 timer.

John Zhang

ADMINISTRERENDE DIREKTØR

Jason Liu
Kevin Wang
Cindy Chen
Lily Li
Demo av kontaktskjema
页眉表单