Er HYSF-kontakter “Hot Swappable” (Live Mating)?

No. Standard wet-mate connectors should NOT be mated or unmated while under electrical load (Live). Doing so can cause electrical arcing, which burns the gold plating on the contacts and destroys the insulation barrier, leading to immediate failure.

“Wet-mate” betyr ikke “Live-mate”.

  • Arcing: Water is conductive. Plugging in a live connector (e.g., 48V or 300V) creates a momentary arc that pits the contact surfaces.
  • Protocol: Always power down the system (turn off the PSU or ROV output) before connecting or disconnecting the cables.
  • Exceptions: While some specialized inductive couplers exist for live mating, our standard pin-and-socket connectors require a power-off protocol for safety.
Bilde av John Zhang

John Zhang

(administrerende direktør og ledende ingeniør)
E-post: info@hysfsubsea.com
Jeg har over 15 års erfaring med undervannskoblingsteknologi og leder HYSFs FoU-team som utformer høytrykksløsninger (60 MPa). Jeg fokuserer på å sikre pålitelighet uten lekkasje for ROV-er, AUV-er og offshore-instrumentering. Jeg fører personlig tilsyn med valideringen av våre tilpassede prototyper.

Har du et komplisert teknisk spørsmål?

Utprøvde løsninger i felten

Et utstillingsvindu for vårt vellykkede samarbeid med globale partnere innen marin robotikk, energi og forskning. Hvert prosjekt gjenspeiler vår forpliktelse til null lekkasjeintegritet og driftssikkerhet.

Start ditt subseaprosjekt med HYSF

Enten du trenger et raskt tilbud på standardkontakter eller en kompleks, spesialtilpasset kabelmontering, står ingeniørteamet vårt klart til å hjelpe deg. Du kan forvente et teknisk svar innen 12 timer.

John Zhang

ADMINISTRERENDE DIREKTØR

Jason Liu
Kevin Wang
Cindy Chen
Lily Li
Demo av kontaktskjema